With high technology for control of three-phase induction motors and permanent magnets synchronous motors – Magnet, the CFW11 Series achieves the performance increase for the most complex drive systems. Design exclusive for industrial or professional use, the CFW11 presents many innovations adding significant benefits to customers, a lot for its simplicity of installation and operation, based in the Plug-and-Play philosophy also allowing simple and quick installation of its accessories.
- Scalar Control (V/F), Vector Control (VVW), Open loop Vector Sensorless and Closed Loop with Encoder
- Senusoidal PWM modulation – Space Vector Modulation
- Overload capacity: ND with 110% current or HD with 150% current in 60 sec.
- RFI Filter built-in (optional)
- DC link Reactor built-in
- Safety stop board (EN 954-1/ ISO 13849-1 compliant)
- Ambient temperature -10 ºC up to 50 ºC
- All the electronic boards are conformally coated classified as 3C2 according to IEC 60721-3-3 standard
- Protection Degree IP20 and NEMA 1 (with accessory) or IP54 (optional)
- SoftPLC function built-in
- Local graphic HMI with real-time clock built-in
- Plug-in modules: I/Os, temperature sensor, encoder and communication network
- 24 V cd power supply board for control feeding
- PLC built-in – PLC11-01 and PLC11-02 (accessory)
- Flash memory module: In few seconds, it is possible to download the programming from a CFW11 to others without powering them up
- USB Port
- Communication protocols: Modbus RTU (RS-232 and RS-485), CANopen, DeviceNet, Profibus DP/DPV1, Profinet, Modbus-TCP, EtherNET/IP, EtherCAT and BACnet
- WLP and SuperDrive G2 free software
- Trace Funcion by WEG Software
Specifications
| Manufacturer: | WEG |
| Series: | CFW11 |
| Model: | CFW11 0002 T6 |
| Application: | general purpose |
| Capacity, kW: | 2,2 |
| Current, А: | 2.9 |
| Main power supply, V: | 660-690 |
| Phase: | 3 |
| Enclosure: | IP20 |
| Overload capacity, % per 1 min.: | 110 |
| Acceleration time, sec: | 0-999 |
| Deceleration time, sec: | 0-999 |
| EMC filter: | RFI filter is optional |
| Analog input: | 2 |
| Digital input: | 6 |
| Analog output: | 2 |
| Digital output: | – |
| Relay output: | 3 |
| RS485 (Modbus RTU): | + |
| PID: | PID-Regulation |
| V/f control mode: | + |
| Sensorless vector control: | + |
| Operation temperature, °С: | -10…..+50 |
| Storage temperature, °С: | -10…..+50 |
| Dimensions (W x H x D), mm: | 300x550x305 |
| Weight, kg: | 34 |