Variable speed drive, Altivar Process ATV900, APM, single 600 V, 175 hp
Manufacturer: Schneider Electric
Part Number: ATV9A0C16S6
Key Specifications
| Range of product | Altivar Process ATV900 |
| Mounting mode | Cabinet mount |
| IP degree of protection | IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 | IP00 for IP21 or IP54 cabinet integration)IEC 60529 |
| Supply frequency | 50…60 Hz +/- 5 % |
| Network number of phases | 3 phases |
| [Us] rated supply voltage | 600 V – 10…15 % |
| Permissible temporary current boost | 1.2 x In 60 s normal duty) | 1.5 x In 60 s heavy duty) |
| Speed drive output frequency | 0.1…599 Hz |
| Nominal switching frequency | 2.5 kHz |
| Switching frequency | 2…4.9 kHz adjustable with derating factor |
| Motor power hp | 175.0 hp at 600 V normal duty | 150.0 hp at 600 V heavy duty |
| Line current | 152.0 A 600 V normal duty) | 131.0 A 600 V heavy duty) |
| Apparent power | 158.0 kVA at 600 V normal duty | 136.0 kVA at 600 V heavy duty |
| Continuous output current | 175.0 A at 2.5 kHz normal duty | 145.0 A at 2.5 kHz heavy duty |
| Maximum transient current | 210.0 A 60 s normal duty) | 217.5 A 60 s heavy duty) |
| Frequency resolution | Display unit 0.1 Hz | Analog input 0.012/50 Hz |
| Minimum switching current | Relay output R1, R2, R3 5 mA 24 V DC |
| Maximum switching current | Relay output R1 resistive, cos phi = 1 3 A 250 V AC | Relay output R1 resistive, cos phi = 1 3 A 30 V DC | Relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC | Relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC | Relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC | Relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC | Relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC | Relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC |