The DB1 Cold Plate unit combines all the functionalities of the proven DC1 series in the smallest IEC-compatible form. With its cold plate technology, this powerful device provides the ideal solution for customers who want to integrate the drive into existing systems without having sufficient space for heatsinks or ventilation. With dimensions of 74mm high, the DB1 Cold Plate needs 40% less of space compared to a drive with active cooling.
- Fast commissioning with 14 basic parameter
- Future proofed – DB1 for all motors up to IE4: standard induction motors, AC induction motors (DAM), permanent magnet motors (PM), brushless DC motors (BLDC), synchronous reluctance motors (SyncRM)
- Detachable Control module
- High overload capability: 150% for 60 sec., 175% for 2 sec.
- Ambient air temperature of 60°C without derating
- CANopen and Modbus RTU on board
- Enclosure IP20
- Integrated EMC filters
- U/F control, vector SL
- DC braking
- International Standards (IEC, cUL, RoHS)
- Accessories: ext. keypad, parameter saving and Bluetooth communication stick, drivesConnect parameter software
Specifications
| Manufacturer: | Eaton |
| Series: | DB1 Gold Plate |
| Model: | DB1-344D1FN-N2CC |
| Product Code: | 197197 |
| Application: | general purpose |
| Capacity, kW: | 1.5 |
| Current, А: | 4.1 |
| Main power supply, V: | 380-480 |
| Phase: | 3 |
| Output frequency, Hz: | 0-500 |
| Enclosure: | IP20 |
| Overload capacity, % per 1 min.: | 150 |
| EMC filter: | internal RFI filter |
| Braking unit: | – |
| Analog input: | 2 |
| Digital input: | 4 |
| Analog output: | 1 |
| Digital output: | 1 |
| Relay output: | 1 |
| RS485 (Modbus RTU): | RS485 (Modbus RTU, CANopen, OP-Bus) |
| Sensorless vector control: | + |
| Operation temperature, °С: | -10…..+60 |
| Storage temperature, °С: | -40…..+60 |
| Dimensions (W x H x D), mm: | 118x130x74 |
| Weight, kg: | 0,7 |